COMMUNICATION >> HILSCHER Protocol Converter
PROTOCOL CONVERTERS
netLINK / netTAP-MPI - Ethernet to MPI / DP / PPI Converter for SIMATIC S7®
Ethernet upgrade for S7-PLCs with MPI/DP/PPI port
As directly mountable or as rmly attachable DIN rail mountable device the adaptors netLINK- and netTAP-MPI are replacing expensive CP communications processors and allow the programming, visualization and control of S7-200®, S7-300® or S7-400® PLCs over Ethernet.
The provided driver integrates into all well-known SIMATIC S7® engineering tools like STEP7® or TIA portal as PG/PC programming interface. The device is setup within the engineering tool or with conventional web browsers over the integrated web con guration pages.
The adaptors are suitable to program or change S7-PLC control programs and may serve to engineer HMI devices with the visualization software WinCC. By supporting the ISO on TCP RFC1006 Ethernet protocol any third party or SIMATIC® visualization stations can be coupled to the PLC. Once integrated into the ofce or plant network and connected to the internet also remote maintenance and logging over a router is possible since plain TCP/IP protocol access mechanisms are used.
Organized in a network direct communication between two or several PLCs over Ethernet can be realized. Even a coupling of PLCs with no own Ethernet port is possible using two adapters in conjunction. Featuring full PROFIBUS diagnostics and Master Class 2 DPV1 services enables unrestricted DP Slave device conguration and parameterization in STEP7®.
Power is supplied by a 24 V DC. If supported by the S7 PLC the netLINK-MPI adaptor may be powered over the DSUB9 connector alternatively and its extra feed-through DSUB9 connector allows the connection of further devices to the same MPI/DP network.
Technical Data
| netLINK MPI | netTAP MPI
|
---|
Operating Temperature Power supply Dimensions (L x W x H) Supply
Processor Interfaces
LEDs Weight Emission Noise Immunity Supoorted PLCs
| ±0°C... +55°C +18... +30 V / approx. 60 mA @ +24 V 65 x 48 x 16 mm Mini-COMBICON 3,81 mm 2-pole or S7 DSub-9 MPI / PROFIBUS netX 50 Fast Ethernet 10/100 BASE-TX, MPI/PROFIBUS 12 MBaud IEC 61158 SYS, COM, ACT, LNK approx. 40 g CISPR 11 Classe A EN 61131-2:2003 SIMATIC S7® 200,300,400 CPU/CPs with MPI/PROFIBUS/PPI interface
| ±0°C... +60°C +18... +30 V / approx. 130 mA @ +24 V 100 x 52 x 70 mm Mini-COMBICON 3,81mm 2-pole
netX 50 Fast Ethernet 10/100 BASE-TX, MPI/PROFIBUS 12 MBaud IEC 61158 SYS, COM, ACT, LNK approx. 150 g CISPR 11Classe A EN 61131-2:2003 SIMATIC S7® 200,300,400 CPU/CPs with MPI/PROFIBUS/PPI interface
|
Highlights
-
Parallel communication to 32 PLCs with up to 16 TCP connections
-
Direct PLC to PLC communication, also as projected connection
-
For all S7 Engineering Tools inclusive TIA Portal
-
Web based con guration, protocol support of RFC1006 and DHCP
-
Full access to PROFIBUS diagnostics and services in STEP7®
-
Automatic DP/MPI baud rate detection
MICRO-CONVERTER
|
---|
Article
| Description
|
---|
NT 50-MPI
| Micro-converter Ethernet TCP/IP to S7-MPI/PROFIBUS-DP (up to 12Mbps) in the box of a NetTAP50. Supply: 24VDC. For the use with STEP®7 of SIEMENS.
|
NL 50-MPI
| Micro-converter Ethernet TCP/IP to S7-MPI/PROFIBUS-DP (up to 12Mbps) in the box of a Profibus-connector. Supply: 24VDC or via PG-Connector. For the use with STEP® of SIEMENS
|
netLINK51 PROXY - PROFIBUS to PROFINET PROXY in connector format
Turning any PROFIBUS slave into PROFINET device
netLINK PROXY integrates a PROFIBUS-DP slave into any superordinate PROFINET network. As connector the device is plugged directly onto the PROFIBUS-DP interface of the DP-Slave and connects to the PROFINET network via its RJ45 socket.
On PROFINET side netLINK behaves like an ordinary IO device. The DP-Slaves process data are mapped in accordance with the present PI-organisations guideline into the PROFINET slot/subslot addressing model. Commissioning is done via the Ethernet port with either a direct connection to the PC or if already installed and during run time via a PROFINET switch. netLINK PROXY is configured with the FDT/DTM based planning, configuration and diagnostic tool SYCON.net.
With few steps netLINK is getting operative. In case there is no slave GSD file available, a scan function is able to identify the slave on PROFIBUS. After the configuration and the I/O process data length is known, SYCON.net converts the parameters automatically into a standardized GSDML file. This file imports to any PROFINET controller configuration utility and gets netLINK into operation effortless. The netLINK Proxy is supplied by 24 V. During mounting the voltage can be tapped comfortably from the DP-Slave and be led to the 2-pin COMBICON connector. The short distance on PROFIBUS makes a terminator unnecessary.
netLINK PROXY a cost-efficient and handy alternative to redevelopments to get existing DP devices integrated straightforward into the PROFINET world.
Highlights
-
Integrates a single DP-Slave into PROFINET network
-
For direct mounting on DP interface
-
Compatible to any PROFIBUS Slave
-
Automatic GSDML file generation from GSD file for PROFINET controller configuration
-
Works in accordance with PI-organizations proxy guideline
MICRO-CONVERTER
|
---|
Article
| Description |
---|
NL 51N-DPL
| Micro converter ProfiNet to PROFIBUS-DP-Link (up to 12MBd) in the box of a Profibus-connector. Power supply: 24VDC.
|
Technical Data
| netLINK 51 PROXY
|
---|
Operating temperature Power Supply Dimensions (L x W x H) Weight Processor
Connectors Emission Noise Immunity LEDs Certifications
| ±0°C... +50°C +18... +30 V / approx. 100 mA @ +24 V 65 x 48 x 16 mm approx. 150 g netX 50 netX 50Mini-COMBICON 2-pole RJ45-female connector DSub 9-pin male connector CISPR 11 Classe A EN 61131-2:2003 SYS, COM,Link, Rx/Tx CE-Sign
|
netTAP 50 - Low-Entry Gateway for Industrial Automation networks
I/O protocol gateway for basic conversions
netTAP 50 is a protocol converter for simple conversions. netTAP 50 converts 1-port Real-Time Ethernet, fieldbus and serial automation protocols. Slave to slave or slave to master conversions are supported. As a master, netTAP 50 provides full master functionality to one slave device only. This makes it easy to integrate a single field device into any higher-level network.
The design impresses with a cost-optimized, compact hardware implementation being reduced to the elementary requirements of a protocol converter. The converter addresses market segments which set the focus on cost savings. The cost-reduced design combined with its countless conversion possibilities makes netTAP 50 an attractive gateway in terms of price and universality.
netTAP is configured and diagnosed by the universal FDT/DTM technology based configuration tool SYCON.net. LED indicators are visualizing status information for rapid on-site diagnostics. The protocol conversions are preprogrammed and loaded as firmware into the device on demand. Conversions needing the same physical network interface can be managed by a single device variant. So a device can be for example a PROFIBUS slave on one hand or a PROFIBUS master by a simple firmware change on the other.
Technical Data
netTAP50 |
|
---|
Operating temperature Power Supply Dimensions (L x W x H) Weight Diagnostic Interface Displays Configuration Connector Mounting Certification RS232/485/422 Emission Noise Immunity
| ±0°C +60°C +18 +30 V / 130 mA @ +24 V 100 x 25 x 70 mm (without connector) approx. 80 g Ethernet, RJ45 female connector SYS, COM,Link, Rx/Tx, protocol specific SYCON.net, Windows® 7 or higher Mini-COMBICON 2-pole DIN-Rail, DIN EN 60715 CE Sign not electrically isolated CISPR 11 Classe A EN 61131-2:2003
|
Highlights
-
Parallel communication to 32 PLCs with up to 16 TCP connections
-
Direct PLC to PLC communication, also as projected connection
-
For all S7 Engineering Tools inclusive TIA Portal
-
Web based conguration, protocol support of RFC1006 and DHCP
PROTOCOL CONVERTER
|
---|
Article
| Technical Data
|
---|
NT 50-RS-EN
| netTAP50 Gateway RS232/422/485 - Ethernet
|
NT 50-CO-RS
| netTAP50 Gateway CANopen - RS232/422/485
|
NT 50-CO-EN
| netTAP50 Gateway CANopen - Ethernet
|
NT 50-DN-RS
| netTAP50 Gateway DeviceNet - RS232/422/485
|
NT 50-DN-EN
| netTAP50 Gateway DeviceNet - Ethernet
|
NT 50-DP-RS
| netTAP50 Gateway PROFIBUS-DP - RS232/422/485
|
NT 50-DP-EN
| netTAP50 Gateway PROFIBUS-DP - Ethernet
|
Maximum Cyclic Process Data
|
| Master | | Slave |
---|
| ASCII | | 1000 | Bytes I/O-Data
|
| CANopen | 1024 |
| 1025 Bytes I/O-Data
|
| CC-Link | |
| 736 Bytes I/O-Data
|
| DeviceNet | 510 | | 510 Bytes I/O-Data
|
| EtherNet/IP | 1008 |
| 1008 Bytes I/O-Data
|
| Modbus RTU | 1024 | | 1024 Bytes I/O-Data
|
| ModbusTCP | 1024 | | 1024 Bytes I/O-Data
|
| PROFIBUS | 488 | | 488 Bytes I/O-Data
|
| PROFINET | 2048 | | 1048 Bytes I/O-Data
|
The maximum convertible number of I/O data of a protocol combination is determined by the protocol with the lower amount if I/O Data.
Note: All technical data may be changed without further notice.
Ordering example: PROFIBUS Master to EtherNet/IP Slave = NT 50-DP-EN
* Master license included; supports Master functionality to one slave (Modbus RTU/TCP without limitations)
netTAP 100 - High-end Gateway for Industrial Automation networks
I/O protocol gateway for demanding conversions
netTAP 100 is the protocol converter for sophisticated conversions and supports 2-port Real-Time Ethernet to serial, Fieldbus to Fieldbus, Real-Time Ethernet to Fieldbus and Real-Time Ethernet to Ethernet automation protocols. It supports slave and master functionality in any combination. Master functionality is unrestricted when licensed.
A memory card slot allows the user to save firmware and configuration data on a removable card. In case of failure all that is necessary to bring the plant back on line within seconds is to move the memory card from the old netTAP 100 onto a spare unit.
Apart from standard protocols, netTAP 100 supports the creation of serial protocols with the Lua-based scripting language netSCRIPT. A full featured development environment is included within the delivery. It allows the comfortable and rapid programming of any proprietary serial protocol as well as the I/O data pre-processing during the conversion into the other field protocol.
Technical Data
netTAP50 |
|
---|
Operating temperature Power Supply Dimensions (L x W x H) Weight Diagnostic Interface Displays Configuration Connector Mounting Certification Emission Noise Immunity
| ±0°C... +60°C +18... +30 V / 130 mA @ +24 V 100 x 25 x 70 mm (without connector) approx. 150 g Mini USB SYS, COM, Link, Rx/Tx, protocol specific SYCON.net, Windows® 7 or higher Mini-COMBICON 2-pole DIN-Rail, DIN EN 60715 CE Sign, UL 508 CISPR 11 Classe A EN 61131-2:2003
|
PROTOKOLLKONVERTER |
---|
Best. Nr.: | Technical Data |
---|
NT 100-CO-DN | netTAP100 Gateway CANopen - DeviceNet |
NT 100-CO-DP | netTAP100 Gateway CANopen - PROFIBUS-DP |
NT 100-DN-CO | netTAP100 Gateway DeviceNet - CANopen |
NT 100-DN-DP | netTAP100 Gateway DeviceNet - PROFIBUS-DP |
NT 100-DP-CO | netTAP100 Gateway PROFIBUS-DP - CANopen |
NT 100-DP-DN | netTAP100 Gateway PROFIBUS-DP - DeviceNet |
NT 100-DP-DP | netTAP100 Gateway PROFIBUS-DP - PROFIBUS-DP |
NT 100-DP-RS | netTAP100 Gateway serial RS232/422/485 - PROFIBUS-DP |
NT 100-RE-RS | netTAP100 Gateway serial RS232/422/485 - fieldbus |
NT 100-RE-CO | netTAP100 Gateway RT-Ethernet - CANopen |
NT 100-RE-DN | netTAP100 Gateway RT-Ethernet - DeviceNet |
NT 100-RE-DP | netTAP100 Gateway RT-Ethernet - PROFIBUS-DP |
MASTERLIZENZ | Master/Controller License for RT-Ethernet, PROFIBUS-DP a.s.o. |
MRPLiezenz | MRP extension for PN master license |
Highlights
-
Parallel communication to 32 PLCs with up to 16 TCP connections
-
Direct PLC to PLC communication, also as projected connection
-
For all S7 Engineering Tools inclusive TIA Portal
-
Web based conguration, protocol support of RFC1006 and DHCP
Maximum Cyclic Process Data
|
| Master | | Slave |
---|
| ASCII | | 1024 | Bytes I/O-Data
|
| CANopen | 7168 |
| 1025 Bytes I/O-Data
|
| CC-Link | |
| 736 Bytes I/O-Data
|
| DeviceNet | 7168 | | 510 Bytes I/O-Data
|
| EtherCAT | 11472 | | 400 Bytes I/O-Data
|
| EtherNet/IP | 11472 |
| 1008 Bytes I/O-Data
|
| Modbus RTU | 11520 | | 11520 Bytes I/O-Data
|
| ModbusTCP | 1024 | | 1024 Bytes I/O-Data
|
| netSCRIPT | | 2048 | Bytes I/O-Data
|
| POWERLINK | | | 298 Bytes I/O-Data
|
| PROFIBUS | 11472 | | 448 Bytes I/O-Data
|
| PROFINET | 11472 | | 2048 Bytes I/O-Data
|
| Seriös | 11472 | | 256 Bytes I/O-Data
|
The maximum convertible number of I/O data of a protocol combination is determined by the protocol with the lower amount if I/O Data.
Note: All technical data may be changed without further notice.
Ordering example: PROFIBUS Master to EtherNet/IP Slave = NT 100-RE-DP
* Master license must be ordered separately (Modbus RTU/TCP without limitations)
netTAP 151 - High-end Gateway for Real-Time Ethernet Networks
I/O protocol gateway for basic conversions
The gateway netTAP 151 transmits IO data bidirectionally between any two industrial Real-Time Ethernet networks. It is the ideal solution for installations with heterogeneous networks or such of the same kind to exchange data across given network boundaries. With more than 25 different combinations of the protocols PROFINET, EtherCAT, EtherNet/IP, POWERLINK, Sercos and Modbus TCP, the device series provides a solution for any conversion.
The integration as simple I/O device into the primary network makes the converter compatible with any common PLC. On the secondary side it works either as I/O device too or controls a subordinate network as a bus master. The length of the I/O data can be scaled to any application and the data in between can be mapped on byte level arbitrarily.
Secure network separation is provided by two Ethernet controllers, each connected to a Dual Ethernet port with integrated switch. That allows realizing star, ring and inline network topologies without further peripherals. Both controllers handle the protocols independent from each other and exchange only the I/O data across a data buffer. An overall data processing time lower than 10 milliseconds is achieved.
The devices can be ordered preloaded with fi rmware and license or unloaded. Unloaded devices minimize the storage costs. Subsequent loading of a firmware configures these devices for any conversion most exible. All devices are commissioned and diagnosed network independent over USB.
Highlights
-
Bridging between two Real-Time Ethernet networks
-
Flexible choice of operating modes Slave/Master or Slave/Slave
-
Effortless integration as standard I/O device
-
Secure network segregation via internal data buffer
-
Fast conversion time less than 10 milliseconds
netTAP151 |
|
---|
Operating temperature Power Supply Dimensions (L x W x H) Weight Service Interface Displays Configuration Connector Mounting Emission Noise Immunity Certification Card Slot
| ±0°C... +60°C +18... +30 V / 190 mA @ +24 V 99 x 22,5 x 114,5 mm (without connector) 121 g Mini USB LED SYS, APL, protokollspezifisch SYCON.net, Windows® 7 Mini-COMBICON 5-pin DIN-Rail, DIN EN 60715 EN55011 / EN55011 / CISPR 11; Classe A EN 61000-6-2 CE-Zeichen, UL, cUL SD-Karte
|
Note: All technical data may be changed without further notice.
Maximum Cyclic Process Data
PROFIBUS | Master | Slave |
---|
EtherCAT EthetNet/IP POWERLINK PROFINET Sercos Modbus TCP
| 9200 11472
11472 11472 11520
| 512 Bytes I/O-Data 1008 Bytes I/O-Data 1490 Bytes I/O-Data 1048 Bytes I/O-Data 240 Bytes I/O-Data 11520 Bytes I/O-Data |
The maximum convertible number of I/O data of a protocol combination is determined by the protocol with the lower amount if I/O Data.
Note: All technical data may be changed without further notice.
Order No.: | PROTOCOL CONVERTER Technical Data |
---|
NT 151-RE-RE | netTAP151 Gateway RT-Ethernet - RT-Ethernet
|
MASTERLIZENZ | Master / Controller License for RT-Ethernet |
MRPLiezenz
| MRP extension for PN master license |